Fixation Correction#

The pEYEpline corrects drift in fixation locations before scanpaths and reading measures are calculated. Drift correction moves each fixation toward the text line it was read from. It is useful when the recorded gaze drifts away from the line during a trial.

The correction is on by default (RUN_FIXATION_CORRECTION: true). Set it to false to disable it.

Text direction#

The script direction comes from Script_direction in the lab configuration of the active stimulus version. LabConfig is loaded per stimulus folder, so a collection that uses stimulus_versions can mix horizontal and vertical sessions.

  • ltr and rtl use the usual vertical line correction. For rtl, the direction is passed to pymovements so that right-to-left line processing is used.

  • ttb is top-to-bottom vertical text. The pipeline transposes fixation coordinates and AOI geometry, so columns become horizontal lines for pymovements, then transposes the corrected locations back. The fixed coordinate is therefore x, while y is preserved.

  • btt is rejected with a clear error. The current stimulus generator does not produce it.

See Configuration for a mixed-direction stimulus_versions example.

Where it runs#

Correction runs after fixation detection and before scanpaths, reading measures and sanity plots. The raw detected fixations are saved first. The corrected fixations are then used by all later stages for that session.

When correction is on#

This is the default:

  • fixations/ contains the corrected fixations.

  • fixations_uncorrected/ contains the raw detected fixations.

  • scanpaths/, reading_measures/ and sanity plots use the corrected fixations.

  • processing_config.aoi_enlargement is none.

  • Corrected fixation files keep the original coordinates in location_x_original and location_y_original.

  • The applied algorithm is stored in correction_algorithm.

When correction is off#

Set RUN_FIXATION_CORRECTION: false to disable correction:

  • fixations/ contains the detected, uncorrected fixations.

  • scanpaths/, reading_measures/ and sanity plots use those uncorrected fixations.

  • fixations_uncorrected/ is not written.

  • processing_config.aoi_enlargement is half_line_spacing, which extends each AOI to the space between lines.

Fixation positions on a stimulus page before and after drift correction

Fixation positions on one stimulus page. Red points are before correction. Blue points are after correction. Grey lines connect the original and corrected positions. Fixations on the final dot overlap before and after correction and stay at the dot.#

All output folders are subfolders of the processed data collection folder:

preprocessed_data/<dcn>/
├── fixations/
│   └── <session>_<trial>_<stimulus>_fixation.csv
├── fixations_uncorrected/
│   └── <session>_<trial>_<stimulus>_fixation.csv
├── scanpaths/
├── reading_measures/
└── sanity_checks/

fixations_uncorrected is therefore part of the processed data collection, not a top-level project folder and not a folder inside internal/.

Settings#

RUN_FIXATION_CORRECTION: true
fixation_correction_algorithm: "wisdom_of_the_crowd"
fixation_correction_kwargs: {}
fixations_uncorrected_folder: "fixations_uncorrected/"
  • RUN_FIXATION_CORRECTION enables or disables the step.

  • fixation_correction_algorithm accepts a single algorithm or wisdom_of_the_crowd. Supported single algorithms are attach, chain, cluster, compare, merge, regress, segment, slice, split, stretch and warp.

  • wisdom_of_the_crowd runs all algorithms and combines their line assignments by majority vote. No kwargs are required; each algorithm uses its own defaults.

  • fixation_correction_kwargs passes extra tuning parameters to the algorithms.

  • fixations_uncorrected_folder is the subfolder name inside the processed data collection.

Direction is not a pipeline setting. It is read from Script_direction in each stimulus version’s lab configuration. Missing values default to ltr.

Final fixation dot#

Each stimulus page ends with a fixation dot. Dot positions can differ by language and collection, so the pipeline reads the geometry from the stimulus config and does not hardcode a position.

Newer stimulus configs write the final-dot geometry directly:

POS_BOTTOM_DOT_X_PX = 1236
POS_BOTTOM_DOT_Y_PX = 920
FIX_DOT_RADIUS = 8

When those keys are absent, LabConfig derives the same values from the existing config with the image generator geometry:

is_ltr = FIX_DOT_X < IMAGE_WIDTH_PX / 2

POS_BOTTOM_DOT_X_PX = (
    IMAGE_WIDTH_PX - MIN_MARGIN_RIGHT_PX
    if is_ltr
    else MIN_MARGIN_LEFT_PX
)

POS_BOTTOM_DOT_Y_PX = int(
    IMAGE_HEIGHT_PX - 2 * RESOLUTION[1] / SCREEN_SIZE_CM[1]
)

FIX_DOT_RADIUS = max(int(0.1 * MIN_MARGIN_LEFT_PX), 7)

The radius therefore depends on the horizontal screen DPI. It ranges from 7 to 9 pixels in the current collections. It is not a fixed constant.

LabConfig stores the result in final_fix_dot_x, final_fix_dot_y and final_fix_dot_radius. If correction is active and the geometry cannot be derived, the run stops with an error. There is no AOI fallback for the final dot.

A fixation counts as a dot fixation only when it is outside the text AOI bounds, with a direction-aware tolerance, and within a tolerance around the dot centre. The tolerance is the larger of four dot radii and the distance from the dot to the nearest text edge, because gaze positions on the dot can be several dot radii away from its centre. This works for horizontal text with a bottom dot and for TTB text with a bottom-left dot. Dot fixations are removed from the correction input before pymovements runs. Correction therefore uses only the real text lines. The dot fixations are reinserted unchanged afterwards. This avoids a fake dot line and prevents text fixations near the last line or column from snapping to the dot.

Dataset overview and codebook#

The dataset overview records the resolved settings in processing_config:

processing_config:
  fixation_correction: true
  fixation_correction_algorithm: wisdom_of_the_crowd
  fixation_correction_kwargs: {}
  aoi_enlargement: none

The codebook has matching fields:

  • dataset.processing_config.fixation_correction

  • dataset.processing_config.fixation_correction_algorithm

  • dataset.processing_config.fixation_correction_kwargs

When fixation_correction is true, the corrected fixations feed scanpaths and reading measures and aoi_enlargement is none. When it is false, the algorithm and kwargs are recorded for reproducibility but were not applied, and the fixation, scanpath and reading-measure outputs are uncorrected.

Recalculation#

Cached fixation files are reused only when they match the current correction setting and algorithm. Changing RUN_FIXATION_CORRECTION or fixation_correction_algorithm invalidates cached fixations. The next run detects fixations again, applies or skips correction, and rewrites the affected downstream outputs.

Current limitations#

  • The pipeline temporarily pins pymovements to the commit that contains the correction API. The pin is removed when a pymovements release includes it.

  • Vertical correction is implemented locally by transposing the geometry. Native vertical support in pymovements is a follow-up.